HomePage | Menus | Use | Parameter settings | Gauge Tools | Cablings | Downloading | Contact |
Langue - Language - Lengua : Français - English - Español
The cablings with TelePcCn Pro
Examples of cablings |
Cabling of a boitier of division(sharing) or distributor |
If we use a case of sharing put into series, the cable joining the PC to the distributor has to contain 5 threads and the signals must not be crossed.
PC DB25
distributor PC
TD 2---------------------/2 TD Sending
RD 3---------------------/3 RD Receiving
0V
7---------------------/7 GND
RTS 4---------------------/4 RTS
CTS 5---------------------/5 CTS
Correspondence of connectors DB9-DB25 |
-
CABLING OF SERIAL PORTS PC
-
Correspondences DB9 / DB25
US signal DB9 DB25
name Name Fr
DCD 1 9 Dated Quarryman Detect Liaison détéctée
RD 2 3 Receive Data Réception of the data
TD 3 2 Passed on Dated Data transmission
DTR 4 20 Dated Air Terminal Ready Terminal ready to receive
GND 5 7 Ground Masse Signal or Mass
DSR 6 6 Dated Set Ready Prêt to work
RTS 7 4 Request To Send Demande of sending
CTS 8 5 Clear To Send Prêt to send
LAUGHED9 22 Boxing Ring Indicator
Cabling without signal of control - CNC NUM puts into series 700 |
Case of the CNC NUM puts into series
700
Without signal of control:
TD 2 -------------/-------------- 3 2 RD Sending
0V
7
-------------/-------------- 7 5 GND
RTS
4 No
connected
|-----
4
7
RTS
Rebouclage
Pontage |
des signaux
CTS
5
-----|
|-----
5
8
CTS
de contrôle
|
DCD
8
-----|
Pontage direct sur les broches
|
It is with this type of
cabling that it is rather necessary to use TelePcCn for a NUM 7XX by
using the control of stream RTS / CTS.
This type of cabling is
the simplest to realize, it requires only an armoured cable 3 threads. The
length of the maximum transmission link for a speed of 9600 Bauds does not have to exceed 25 metres. With
good conditions of transmissions ( few parasites) we can affect
approximately 40 metres. You should not connect the mass of the cable with
the frame of the machine.
Cabling with signal of control - CNC NUM puts into series 700 |
With signal of control:
TD 2 -------------/-------------- 3 2 RD Receiving
0V 7
-------------/-------------- 7 5 GND
RTS 4
-------------/-------------- 6 6 DSR
CTS 5
-------------/-------------- 20 4 DTR
DCD 8 -----|
|-----
4
7 RTS
Rebouclage
|
|
des signaux
Cabling with signal of control - CNC NUM puts into series 1000 |
Case of the CNC NUM puts into series 1000-1020-1040-1060
CNC
PC DB25
DB9
TD
2
-------------/-------------- 3 2 RD Réception
0V 7
--------------/----------------- 7 5 GND
RTS
4
-------------/-------------- 5 8 CTS
CTS
5
-------------/-------------- 4 7 RTS
DCD
8
-----|
|-----
6
6
DSR
Rebouclâge
|
|
des signaux
DTR
20
----|
|-----
8
1
DCD
de contrôle
|
|
DSR 6 -----| |----- 20 4 DTR
( Direct Decking on brooches at the level of the
connector)
Parameter setting of the connection puts into
series
CNC NUM
1060 PC
N of
Line
:0
or 1 Port COM
: COM N
Speed in
sending :9600
Speed of trans. :9600 or
more
Speed in
receiving :9600
Bit of start
:1
Bits of
dated :8 Bits
of data :7
Bit of
stop
:1 Bit of
stop :1
Parity
:without
Parity
:pair
Protocol
:without
Control of stream : RTS / CTS
Problems of reception in the case of a CNC NUM on
1060
In certain cases, according to the used version of Windows and the
power of the microphone computer, it is necessary to reduce the speed of
reception of the programs.
PARAMETER SETTINGS - CNC NUM on 1060
****************************************
Here is the configuration to create on the CNC NUM on
1060
PARAMETER SETTING OF LINES SERIES
- 1 - Parameter setting Configuration 1
(Sending)
Number of
line :line
1
Standard :RS232
Speed of
receiving :9600
Speed of
sending
:9600
Nbr of bits of start
:1
Nbr of bits of dated
:8
Nbr of bits of
stop :1
Parity
:without
Protocol
:without
Control of
stream : RTS / CTS
Logical
name
:Com1
Configuration 1/12 :validated
- 2 - Parameter setting Configuration 2
(Receiving)
Number of
line :line
1
Standard
:RS232
Speed of
receiving :600
Speed of
sending
:600
Nbr of bits of start
:1
Nbr of bits of dated
:8
Nbr of bits of
stop
:1
Parity
:without
Protocol :without
Control of
stream : RTS / CTS
Logical
name
:Com2
Configuration
2/12 :validated
During the sending of a program (PC - > CN) you have to choose the configuration 1/12
(Com1).
During the receiving of a program (CN
- > PC) you have to choose the configuration 2/12
(Com2).
The selection is made with the arrows of the keyboard <- ->.
Case of the NUM 760 F with embeded reader GNT 27 and taken male "Jeager" 27 brooches.
CNC Jeager 27
Broches Mâle
PC DB25
TD 2 - ----------/--------- 3 RD Receiving
RD 3 -----------/---------- 2 TD Sending
0V
7
----------/---------- 7 GND
RTS
4 No
connected |--- 4 RTS
Rebouclage
|
des signaux
CTS
5
---|
|---
5
CTS
de contrôle
|
DCD
8
---|
|
DTR 20 ---|
Disconnect the reader and link the cable with the free grip DB 25
' in the air '.
It's better to realize a cable of connection without signal of control.
To receive the information from the bench EPB, it is necessary to realize a simplified cable.
EPB DB 9 PC DB25
RD 2 --------------/------------- RD 3
TD 3 --------------/------------- TD 2
GNG 5 --------------/------------- GND 7
RTS 7 ---| |--- RTS 4
CTS 8 ---| Pont |--- CTS 5